ผลการค้นหา

ค้นหาเฉพาะ:
Found 151 results containing the words:product
  • Calibrate electrical safety testers to international standards

    EN 50191, Electrical Safety Testing Standard for the Erection and Operation of Electrical Test Equipment

    บทความ
  • Replacing PACE 6000 with the 6270A Modular Pressure Controller/Calibrator

    See the benefits of upgrading the GE Druck PACE 6000 to the Fluke 6270A & learn steps for configuring and installing the 6270A. Get the details here.

    บทความ
  • Shopping for a multi-product electrical calibrator: Seven things you must consider

    How do you choose a multi-product electrical calibrator? They are not all the same. Read this short blog post to learn seven essential points to consider.

    บทความ
  • 2015 World Metrology Day Message

    Read this short blog post to see how Fluke Calibration contributes in this year's World Metrology Day theme, “Measurements and Light”.

    บทความ
  • Six questions to ask before you choose a pressure calibration solution

    Fluke Calibration produces the broadest range of electrical, RF, temperature, pressure & flow calibration instruments & software that help measurement professionals around the globe.

    บทความ
  • Opportunities to learn about calibration and metrology

    calibration education, metrology education, web seminars, software user groups, application notes, learn about calibration, learn about metrology

    บทความ
  • Establishing calibration intervals for Fluke products

    Fluke Calibration produces the broadest range of electrical, RF, temperature, pressure & flow calibration instruments & software that help measurement professionals around the globe.

    บทความ
  • MET/BASE Support Schedule

    Fluke Calibration produces the broadest range of electrical, RF, temperature, pressure & flow calibration instruments & software that help measurement professionals around the globe.

    บทความ
  • Getting started in pressure calibration: a guide to breaking down the barriers

    If you are currently outsourcing or turning away pressure calibration business, you may be doing so unnecessarily. The barriers to enter the pressure calibration business can be overcome fairly easily.

    บทความ
  • Why Calibrate Test Equipment?

    Why calibrate test equipment? What makes it go out of cal? What happens when you send equipment for calibration? When should you calibrate? Learn here.

    บทความ
  • Platinum Resistance Thermometers (PRT)

    A platinum resistance thermometer (PRT) is a thermometer constructed from a high purity platinum element (wire-wound coil or thin film) placed in a tube of metal or glass and sealed with an inert atmosphere and/or mineral insulator.

    บทความ
  • Thermometer Readout Selection Guide

    Precision thermometer readout from Fluke Calibration is easy to use, very accurate, and designed for calibration. Contact us today for more information.

    บทความ
  • Why buy Primary Standards from Fluke Calibration?

    Fluke Calibration’s fixed-point cells benefit from more than 20 years of experience in research, design, and manufacturing. Four types of cells are available: traditional size cells, “mini” quartz cells, new “mini” metal-cased cells, and small stainless steel “X” cells

    บทความ
  • Making the Right Choice for Your Temperature Readout

    Fluke Calibration produces the broadest range of electrical, RF, temperature, pressure & flow calibration instruments & software that help measurement professionals around the globe.

    บทความ
  • Pressure calibration specifications - A rude awakening!

    Compared to electrical calibration, my introduction to pressure calibration was a rude awakening! In pressure calibration, specifications sometimes refer to the “m” and sometimes to the “b”, sometimes together but not always. Plus there are terms that are unique to each manufacturer. Having said that, there are reasons for all of this

    บทความ
  • Using MET/TEMP II FAQs

    MET/TEMP II expects ALL test probes to be in the same heat source at the same time. Since the software only supports one reference probe

    บทความ
  • Frequently Asked Questions for Temperature Calibration Software

    Quick Links-Download Demos, Updates, Service Releases, etc.Technical SupportQuestions about Fluke Calibration Temperature software? This page answers some of the most common questions concerning our software products.All Fluke Calibration temperature calibration software:Q. What version of Windows® is required to run Fluke Calibration Temperature software?A. Please refer to the table below for Windows® compatibility information for the latest version of each software indicated: Software \ Windows®98/98SENT4...

    บทความ
  • To what extent can the calibration process be automated?

    Automation of the pressure calibration process has many potential benefits, including increasing productivity, ensuring better pressure measurements

    บทความ
  • World Metrology Day message from Fluke Chief Corporate Metrologist Jeff Gust

    World Metrology Day 2014A message from Fluke Chief Corporate Metrologist Jeff GustWorld Metrology Day commemorates the signing of the Meter Convention on May 20, 1875. Those who are dedicated to metrology, the science of measurement, recognize this day each year as their time to celebrate the importance of measurements. Fluke Corporation joins enthusiastically in this annual celebration, as we have a long history of dedication to metrology. The theme for World Metrology Day 2014 is “Measurements...

    บทความ
  • 9100 Universal Calibration System

    9100 from Fluke Calibration is the world’s best value multiproduct calibrator can calibrate over 15 different equipments including power meter, insulation tester and oscilloscopes.

    ผลิตภัณฑ์
  • ITS-90 Fixed-Point Cells

    ITS-90 fixed-point cells from Fluke Calibration is constructed in ultra clean labs, using high-density, high-purity graphite crucibles containing metal samples with purity of at least 99.9999 %.

    ผลิตภัณฑ์
  • Release: MET/TEAM version 3.0.0 (with MET/CAL version 10.2.0)

    Release: MET/TEAM version 3.0.0 (with MET/CAL version 10.2.0) (.iso)Documents:MET/TEAM version 3.0.0 (with MET/CAL version 10.2.0) (.pdf)MET/TEAM 3.0.0 ReadMe (.pdf)MET/CAL 10.2.0 ReadMe (.pdf)MET/TEAM Installation Guide (Updated for version 3.0) (.pdf)Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 3.0.0 and MET/CAL version 10.2.0 release is a a major update to MET/TEAM and MET/CAL software. This update includes new features, improvements, bug fixes, and minor...

    บทความ
  • MET/TEMP II Software Download

    MET/TEMP II Software Download (.exe)TITLEVERLinksMET/TEMP II5.2Product PageDescriptionWhen downloaded, this file can be run to install MET/TEMP II. There is no free demo/trial version of 5.2. In order to install MET/TEMP II v5.2, you must purchase the software and obtain a serial number. The installation process prompts you to enter the serial number. Version 5.2 does not accept serial numbers from previous versions of MET/TEMP II. The serial number will be located on a sticker on the CD pouch....

    บทความ
  • MET/TEAM® v3.3.0 and MET/CAL® v11.0.0 Software Trial

    Release: MET/TEAM version 3.1.1 (with MET/CAL version 10.5.0) (.iso)Documents:MET/CAL 10.5.0 Readme (.pdf)MET/TEAM Installation Guide (.pdf)MET/TEAM 3.1.1 Readme (.pdf)Update Instructions for MET/TEAM 3.1.1 and MET/CAL 10.5.0 (.pdf)This update is not for MET/CONNECT Customers. Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 3.1.1 release is a a minor update to MET/TEAM software. This update includes new features, improvements, bug fixes, and minor updates.You...

    บทความ
  • MET/TEAM version 2.2 (with MET/CAL version 9.1)

    MET/TEAM version 2.2 (with MET/CAL version 9.1) (.iso)Documents:MET/CAL 9.1.0 Readme (.pdf)MET/TEAM 2.2.0 Readme (.pdf)Updating to MET/TEAM 2.2 and MET/CAL 9.1 (.pdf)Current MET/TEAM Customers: What you need to know prior to updatingThere has been a major change to the MET/TEAM database which means updating to version 2.2 is a multistep process that could take from 8 to 24 hours depending on your database, server configuration, and network environment.There has been a major change to MET/CAL regarding...

    บทความ
  • MET/TEAM version 2.1 with Update 1 (with MET/CAL version 9.0 with Update 1)

    MET/TEAM version 2.1 with Update 1 (with MET/CAL version 9.0 with Update 1) (.iso)Documents:MET_TEAM_2_1_2_readme (.pdf)METCAL_9.0.0_ReadMe (.pdf)Please read the MET/TEAM Readme file before installing the upgrade.Please note that upgrading from any previous version of MET/TEAM will require you to re-request all of your licenses via email once the upgrade is complete! You must provide your original product codes and gold number(699XXXX) as two separate product code entry lines.If you are upgrading...

    บทความ
  • Fluke DAQ Software

    Fluke DAQ Software (.zip)Discontinued ProductThis product has been discontinued. The download is still available for existing users to download for installation as necessary.DescriptionFluke DAQ 6.0.4 application software for use with Fluke data acquisition and temperature scanning products (2638A, 1586A, 2640A, 2645A, 2680A, 2686A). Version 6.04 is an update to Version 6.03.Evaluation Mode:Without an activation key this program will run for 40-hours of cumulative run-time in Evaluation (DEMO) mode....

    บทความ
  • 96270A RF Reference Source Firmware Upgrade

    96270A RF Reference Source Firmware Upgrade (.ldr)Serial Number RangeBackward CompatibilityDateFirmware RevisionExplanationsAllAll previous versions 96270AApril 2, 2019V1.13Extend capability of previous 96270A models to accept Rohde & Schwarz NRPxxT power sensors.Full list of all sensors recognised by 96270 with install firmware V1.13 installed:Older NRP-Z51, NRP-Z52, NRP-Z55, NRP-Z56, NRP-Z57and NRP-Z58Now extended to include:New: NRP18T, NRP18TN, NRP33T, NRP33TN, NRP40T, NRP40TN, NRP50T, NRP50TN,...

    บทความ
  • WinFlash Free Utility

    WinFlash Free Utility (.exe)Additional Downloads: WinFlash64™ 2.20 (64bit OS) (.exe)PC BasedFree Utilities - WinFlash™TITLEVERUSE WITHWinFlash™2.202011.10.05PPC2+, PPC3, PPC4, PPCH, PPCHG, PPCK+, MFC-CB, molbox1, molbox1+, molbox RFM, PG7000, RPM3, RPM4, RPM4-AD, RPM4-AF, RPM4-E-DWTWinFlash64™(64bit OS)2.202011.10.05PPC2+, PPC3, PPC4, PPCH, PPCHG, PPCK+, MFC-CB, molbox1, molbox1+, molbox RFM, PG7000, RPM3, RPM4, RPM4-AD, RPM4-AF, RPM4-E-DWTDescriptionFirmware upgrade utility. This program...

    บทความ
  • Update: MET/TEAM version 2.2.1 (with MET/CAL version 9.1.1)

    Update: MET/TEAM version 2.2.1 (with MET/CAL version 9.1.1) (.iso)Documents:MET/CAL 9.1.1 Readme (.pdf)MET/TEAM 2.2.1 Readme (.pdf)Updating to METTEAM 2.2.1 and METCAL 9.1.1 (.pdf)Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 2.2.1 and MET/CAL version 9.1.1 release is a stability update to previous MET/TEAM and MET/CAL software. This update includes bug fixes and minor updates.Upgrading from any previous version of MET/TEAM will require you to re-request...

    บทความ
  • Unit of Measure Converter Free Utility

    Unit of Measure Converter Free Utility (.exe)TITLEVERUSE WITH Unit of Measure Converter Free Utility2.01a2006.08.15All Products Instructions:Download and run the file. The installation program will prompt you through the process.DescriptionThe Unit of Measure Converter is a free ActiveX control distributed by Fluke Calibration. This program can be run stand alone or built into other applications. Use the [Show Help] menu choice for details on using this tool.Warning - Fluke Calibration has made...

    บทความ
  • RPM4-AD v1.00f Embedded Software

    RPM4-AD v1.00f Embedded Software (.bin)TITLEVERUSE WITHNOT FOR USE WITHRPM4-AD™1.00f2010.12.28RPM4-ADDo NOT use with NON "-AD" (Air Data)RPM4 ModelsInstructions:Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.If your product has an...

    บทความ
  • RPM4 v1.01I Embedded Software

    RPM4 v1.01I Embedded Software (.bin)TITLEVERUSE WITHNOT FOR USE WITHRPM4™1.01I2019.04.28RPM4Note: If you have a special RPM4model use these links:RPM4-AD™RPM4-AF™RPM4-E-DWT A70M/A7M-AF™RPM4-E-DWT™Please contact our Calibration and Repair department at 602.773.4782 if you recently upgraded to version 1.01f or plan to upgrade from 1.01f to another version. The upgrade path from 1.01f may cause a potentially significant metrological error.Instructions:Download the file.Run Winflash and select...

    บทความ
  • RPM3 v1.02j Embedded Software

    RPM3 v1.02j Embedded Software (.bin)TITLEVERUSE WITHRPM3™1.02j2005.06.27RPM3Instructions:Do Not use with HGC-30000-AF!Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.If your product has an model number ending in "-AF", it requires...

    บทความ
  • Release: MET/TEAM version 3.3.0 (with MET/CAL version 11.0.0)

    Release: MET/TEAM version 3.3.0 (with MET/CAL version 11.0.0) (.iso)Documents:MET/TEAM 3.3.0 Readme (.pdf)MET/TEAM Installation Guide (.pdf)MET/CAL 11.0.0 Read Me (.pdf)Updating to METTEAM 3.3.0 and METCAL 11.0.0 (.pdf)Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 3.3.0 release is a minor update to MET/TEAM software. The MET/CAL version 11.0.0 release is a major update to MET/CAL software. This update includes new features, improvements, bug fixes, and minor...

    บทความ
  • Release: MET/TEAM version 3.2.0 (with MET/CAL version 10.6.0)

    Release: MET/TEAM version 3.2.0 (with MET/CAL version 10.6.0) (.iso)This update is not for MET/CONNECT Customers. Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 3.2.0 release is a a minor update to MET/TEAM software. This update includes new features, improvements, bug fixes, and minor updates.You may upgrade from version 3.0.0, 3.1.0, or 3.1.1 directly to version 3.2.0.Upgrading from version 3.x.x of MET/TEAM will not require you to re-request your licenses.Upgrading...

    บทความ
  • Release: MET/TEAM version 3.1.1 (with MET/CAL version 10.5.0)

    Release: MET/TEAM version 3.1.1 (with MET/CAL version 10.5.0) (.iso)This update is not for MET/CONNECT Customers. Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 3.1.1 release is a a minor update to MET/TEAM software. This update includes new features, improvements, bug fixes, and minor updates.You may upgrade from either version 3.0.0 or 3.1.0 directly to version 3.1.1.Upgrading from version 3.0.0 or 3.1.0 of MET/TEAM will not require you to re-request your...

    บทความ
  • Release: MET/TEAM version 3.1.0 (with MET/CAL version 10.5.0)

    Release: MET/TEAM version 3.1.0 (with MET/CAL version 10.5.0) (.iso)Documents:MET/TEAM 3.1.0 Readme (.pdf)MET/CAL 10.5.0 Readme (.pdf)MET/TEAM Installation Guide (.pdf)Update Instructions for MET/TEAM 3.1.0 and MET/CAL 10.5.0 (.pdf)This update is not for MET/CONNECT Customers. The MET/CONNECT version of this release is available here.Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 3.1.0 and MET/CAL version 10.5.0 release is a a major update to MET/TEAM and...

    บทความ
  • PPCK+ v1.00m Embedded Software

    PPCK+ v1.00m Embedded Software (.bin)TITLEVERUSE WITHPPCK+™1.00m2005.01.05PPCK+Instructions:Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.If your product has an model number ending in "-AF", it requires specific "-AF" embedded software.The...

    บทความ
  • PPCH-G v1.02k Embedded Software

    PPCH-G v1.02k Embedded Software (.bin)TITLEVERUSE WITHPPCH-G™1.02k2023.11.08PPCH-GInstructions:Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.If your product has an model number ending in "-AF", it requires specific "-AF" embedded...

    บทความ
  • PPCH-G v1.02f Embedded Software

    PPCH-G v1.02f Embedded Software (.bin)TITLEVERUSE WITHPPCH-G™1.02f2012.04.04PPCH-GInstructions:Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.If your product has an model number ending in "-AF", it requires specific "-AF" embedded...

    บทความ
  • PPCH 1.01n Embedded Software

    PPCH 1.01n Embedded Software (.bin)TITLEVERUSE WITHPPCH™1.01n2013.07.22PPCHInstructions:Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.If your product has an model number ending in "-AF", it requires specific "-AF" embedded software.The...

    บทความ
  • PPC4E v1.2.6.15 Embedded Software

    PPC4E v1.2.6.15 Embedded Software (.bin)TITLEVERUSE WITHPPC4E™1.2.6.15PPC4EInstructions:Download the file by clicking on "PPC4E v1.2.6.15.bin".Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.If your product has an model number ending in "-AF", it...

    บทความ
  • PPC4 v1.2.6.14 Embedded Software

    PPC4 v1.2.6.14 Embedded Software (.bin)TITLEVERUSE WITHPPC4™1.2.6.14PPC4 (including -AF models)Instructions:Download the file by clicking on "PPC4 v1.2.6.14.bin".Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.The updating of embedded software should...

    บทความ
  • PPC3 v1.03d Embedded Software

    PPC2-AF v1.01e Embedded Software (.bin)TITLEVERUSE WITHPPC3™1.03d2011.10.21PPC3 (including -AF models)Instructions:Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.The updating of embedded software should only be performed after...

    บทความ
  • PPC2-AF v1.01e Embedded Software

    PPC2-AF v1.01e Embedded Software (222.5 KB)TITLEVERUSE WITHPPC2-AF™1.01e2006.11.17PPC2-AFTITLEVERUSE WITHPPC2-AF™1.01e2006.11.17PPC2-AFInstructions:Do Not use with PPC2+!This software revision affects only the PPC2-AF on-board routines for calibration of the PPC2-AF's RPTs. It has no effect on regular operation. This new release is recommended for all PPC2-AF units, in particular those on which difficulty with calibration of the Lo Reference Pressure Transducer has been encountered. The FCAL...

    บทความ
  • PPC2+ v2.02f Embedded Software

    PPC2+ v2.02f Embedded Software (.bin)TITLEVERUSE WITHPPC2+™2.02f2002.08.13PPC2+TITLEVERUSE WITHPPC2+™2.02f2002.08.13PPC2+Instructions:Do Not use with PPC2-AF!Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.If your product has an...

    บทความ
  • 9118A Thermocouple Calibration Furnace

    The Fluke Calibration 9118A Thermocouple Calibration Furnace is a horizontal, open-ended tube furnace with a temperature range of 300 °C to 1200 °C.

    ผลิตภัณฑ์
  • Fluke 9500C High-Performance Oscilloscope Calibrator

    Achieve precise calibration for oscilloscopes up to 4GHz with the Fluke 9500C. Features Active Head Technology™ for efficient, automated multi-channel calibration.

    ผลิตภัณฑ์
  • 5960A Triple Point of Argon System

    Fluke Calibration 5960A calculates argon triple point using a reproducible process, produces a 30-hour temperature plateau & increases SPRT calibration efficiency.

    ผลิตภัณฑ์
  • 5790B AC Measurement Standard

    The 5790B AC Measurement Standard is a multi-purpose ac measurement and transfer standard designed for the most demanding calibration applications.

    ผลิตภัณฑ์
  • 52120A Transconductance Amplifier

    Fluke Calibration 52120A Transconductance Amplifier supplies dc currents up to 100 amps & ac currents up to 120 amps, with accuracies up to 140 ppm.

    ผลิตภัณฑ์
  • PG7000 Ver 2.01 Embedded Software

    PG7000 Ver 2.01 Embedded Software (.bin)TITLEVERUSE WITHPG7000™2.01PG7102, PG7302 or PG7601Instructions:TITLEVERUSE WITHPG7000™2.01PG7102, PG7302 or PG7601Instructions:-Ver 2.00 UsersYour PG7000™ time and date will not operate with Ver 2.01 until a hardware change is implemented.-Ver 1.0x UsersVer 2.01 is a major revision which should be accompanied by hardware changes. Contact a Fluke Calibration Authorized Service Center for additional information.Download the file. Run Winflash and select...

    บทความ
  • 5080A High Compliance Multi-Product Calibrator

    5080A Multi-Product Calibrator calibrates digital & analog meters up to 800 mA for ac/dc voltage & voltage up to 50 V for ac/dc current. Request a quote today!

    ผลิตภัณฑ์
  • National Instruments LabView® driver for Fluke data acquisition instruments

    National Instruments LabView® driver for Fluke data acquisition instruments (.zip)This driver is compatible with these Fluke data acquisition products:2680 Series Data Acquisition Systems2640A NetDAQ Data Acquisition Unit2645A NetDAQ Data Acquisition Unit

    บทความ
  • molbox1+ or molbox1+S v6.01 Embedded Software

    molbox1+ or molbox1+S v6.01 Embedded Software (.bin)TITLEVERUSE WITHmolbox1+/molbox1+S™6.012016.12.16molbox1+/molbox1+STITLEVERUSE WITHmolbox1+/molbox1+S™6.012016.12.16molbox1+/molbox1+SThis flash is intended ONLY for molbox1+ or molbox1+S with the Fluke Calibration logo: on the front panel, serial number 2000 and above. Attempted use on any other molbox will result in an inoperable molbox unless the molbox1 hardware is upgraded to a molbox1+.For a molbox1 WITHOUT the Fluke Calibration logo,...

    บทความ
  • molbox1 v5.41 Embedded Software

    molbox1 v5.41 Embedded Software (.bin)TITLEVERUSE WITHmolbox1™5.412016.12.16molbox1TITLEVERUSE WITHmolbox1™5.412016.12.16molbox1Instructions:Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.The updating of embedded software should...

    บทความ
  • molbox RFM™ v1.20d Embedded Software

    molbox RFM™ v1.20d Embedded Software (.bin)TITLEVERUSE WITHmolbox RFM™1.20d2011.10.17molbox RFMTITLEVERUSE WITHmolbox RFM™1.20d2011.10.17molbox RFMInstructions:Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.The updating of...

    บทความ
  • LabVIEW Drivers, Pressure and Flow Calibration Products

    LabView® drivers for Pressure and Flow Calibration Products:6270A Modular Pressure Controller/Calibrator »  LabView® drivers for Pressure and Flow Calibration Products:6270A Modular Pressure Controller/Calibrator » 7250 Series Pressure Controller/Calibrator » 7615 Hydraulic Pressure Controller/Calibrator » 7750i Air Data Test Set » molbox1+ Mass Flow Terminal » PPC4 Pressure Controller/Calibrator » PPCH Hydraulic Pressure Controller/Calibrator » RPM4 Reference Pressure...

    บทความ
  • LabView Drivers

    LabVIEW driver for PPC3 and PPCH (.exe)Additional Downloads:LabVIEW driver for PPC2+ and PPCK+ (.exe)LabVIEW driver for PPC2 and PPCK (.exe)LabVIEW driver for RPM3 (.exe)LabVIEW driver for RPM4 (.exe)LabVIEW driver for molbox (.exe)LabVIEW driver for molbox RFM (.exe)LabView® drivers for Pressure ProductsUSE WITHVERDOWNLOADPPC3™DescriptionLabView is a registered trademark of National Instruments Corp.Instructions:As noted by the table, some of the LabView Drivers support more than one product....

    บทความ
  • Interface-it v3.81

    Interface-it v3.81 (.exe)Interface-it Temperature Calibration SoftwarePosted: 11/27/2007Description: This version includes drivers for the new 914x series Field Metrology Wells as well as 917x series Metrology Wells.Size: 2.2MB** INTERFACE-IT MAY NOT BE FULLY COMPATIBLE WITH WINDOWS® VISTA  & WINDOWS® 7 **Fluke Calibrations's Interface-it Software Version 3.81 allows nearly all our dry-wells, baths and controllers that are equipped with an RS-232 interface to be controlled remotely from a...

    บทความ
  • COMPASS® for Pressure Version 4 Release Notes

    Download COMPASS® for PressureVersion 4 Releases4.2 (2012.07.27)ADDCP-115%4COMPASS for Pressure now supports the calibration functions of CalTool for RPTs. This functionality allows users to fully adjust and report calibration results for supported Fluke products. Sample tests are included with COMPASS that support automated collection of as received data and as left data with an adjustment in between. Review the CalTool for RPTs application note for details. The COMPASS CalTool implementation supports...

    บทความ
  • CalTool for RPTs Free Utility

    CalTool for RPTs Free Utility (57.61 MB)TITLEVERUSE WITHDOCUMENTSCalTool™ for RPTs Free Utility1.10.0.252021.05.11PG7000, PPC2, PPC2+, PPC2 AF, PPC3, PPC4, PPCK, PPCK+, RPM1, RPM3, RPM4, PPCH, PPCH-G, molbox1, molbox RFMCalTool for RPTs uses an on line HTML help system that is installed with the program. Install and run CalTool then select the [Help] menu to access the help system.(Note: As a result of PC specific security settings the help may not display correctly when viewed over the Internet....

    บทความ
  • 8588A & 8558A Firmware, Update by USB

    8588A & 8558A Firmware, Update by USB (.zip)TITLEUSE WITH8588A & 8558AAllThe updating of embedded software should only be performed after given specific instructions to do so from Technical Support or a Fluke Calibration Authorized Service Center.If the update isn't performed properly, your product may be inoperable until it is.Instructions to update by USBFluke 85xx update v1.32To update a Fluke 8588A/8558AAn empty USB stick (of greater than 10Mbytes) will be required. This should be formatted using...

    บทความ
  • 8270A/8370A Embedded Software

    8270A/8370A Embedded Software (.zip)TITLEUSE WITH8270A/8370A8270A/8370AThe updating of embedded software should only be performed after given specific instructions to do so from Technical Support or a Fluke Calibration Authorized Service Center.If the update isn't performed properly, your product may be inoperable until it is.Instructions to update by the USB port on the rear panel of the 8270A/8370AUpdating the firmware (embedded software) of an 8270A or 8370A pressure controller requires only a...

    บทความ
  • 6270A Embedded Software, Update by USB

    6270A Embedded Software, Update by USB (.zip)Additional Downloads:6270 PCM v104 USB (.zip)Click here to update by serial RS-232 port.TITLEUSE WITH6270A6270AThe updating of embedded software should only be performed after given specific instructions to do so from Technical Support or a Fluke Calibration Authorized Service Center.If the update isn't performed properly, your product may be inoperable until it is.Instructions to update by the USB port on the rear panel of the 6270AUpdating the PCM (Pressure...

    บทความ
  • 6270A Embedded Software, Update by Serial RS-232 Port

    6270A Embedded Software, Update by Serial RS-232 Port (.zip)Click here to update by USB.TITLEUSE WITH6270A6270AThe updating of embedded software should only be performed after given specific instructions to do so from Technical Support or a Fluke Calibration Authorized Service Center.If the update isn't performed properly, your product may be inoperable until it is.Instructions to update by the RS-232 serial port on the rear panel of the 6270AThe below procedure updates the main firmware. Updating...

    บทความ
  • How to Accurately Calibrate a Hygrometer

    Get step-by-step instructions on how to accurately calibrate a hygrometer or other humidity sensor including why it’s important, techniques, and tips.

    บทความ
  • 6 ways to maximize instrumentation calibration success

    To minimize plant downtime and keep operations up and running, follow this guidance to ensure smooth instrumentation calibration.

    บทความ
  • 1586A Firmware

    1586A Firmware (.zip)TITLEUSE WITH1586A 1.06.01 Firmware1586ATITLE1586A FirmwareFirmware update V 1.06.01 (2021 June) made the following changes:Changed connection timeout from 100 mSec to 1 Sec to correct connection timeout errors on low latency connections.Changed default scan count from 1 (single shot) to 0 (Infinite), by default instrument will now scan continuously until user stops it.Corrects an issue with user defined Alarm and Timestamp configuration getting lost.Note: Users of 2680A-APSW...

    บทความ
  • Temperature and pressure, nuclear fusion calibration at the National Ignition Facility

    The “manufacturing” process here relies on “shots” of laser energy focused on a target the size of a BB.The product: a nuclear reaction six times hotter than the core of the sun . . . and a growing understanding of fusion reactions that could one day free the planet from dependence on dwindling fossil fuels.Here at the National Ignition Facility (NIF) at California’s Lawrence Livermore National Laboratory, scientists are working to create nuclear fusion reactions that unleash more energy...

    บทความ
  • Automating temperature sensor calibration with the Fluke Calibration 1586A Super-DAQ

    Use the 1586A Super-DAQ to automate temperature sensor calibration The 1586A Super-DAQ Precision Temperature Scanner provides a unique feature for automating sensor calibration that can greatly increase your lab productivity—without a PC and software. When the Super-DAQ is connected to a Fluke Calibration dry-well or fluid bath, it can control the temperature source to run the calibration automatically. You simply program the number of set-point temperatures and their values, select a scan sequence,...

    บทความ
  • 10 reasons you need a 1594A or 1595Aa Super-Thermometer

    With ratio accuracy as good as 0.06 ppm (0.000015 °C) the Fluke Calibration Super-Thermometer is sure to become a highly valued instrument in your calibration laboratory. It is an ideal choice for applications that previously required the use of complex and expensive bridges, such as calibrating SPRTs, PRTs, and thermistors.10 reasons to choose the Super Thermometer for your high accuracy temperature measurements.1. Accurate enough for the primary lab, economical enough for the secondary labThe...

    บทความ
  • Proper calibration of industrial temperature process systems

    Temperature measurement is a critical parameter in many industrial processes. As a result, these processes generally use installed thermometers or temperature transducers. Proper calibration of these installed systems has always presented a challenge. Traditionally, simulators are used to provide in-situ calibration of the electronic portions of these systems. Although this is a valid technique for the calibration of the electronics, considerable inaccuracies are introduced by the sensor itself.The...

    บทความ
  • Fluke Thermal Imaging: The Key to Meeting NFPA 70B Standard

    The NFPA changed its recommended practice for electrical equipment maintenance to a standard. This means that proper maintenance is now required to keep electrical systems safe and reliable for workers. The purpose of NFPA 70B is to safeguard persons, property, and processes from risks associated with electrical equipment malfunction or failure. Maintenance is crucial for achieving this goal. Fluke Ti480 PRO Infrared Camera is one of many Fluke thermal imagers available to help technicians comply...

    บทความ
  • Conveyor system maintenance efficiency with the Fluke ii910 Precision Acoustic Imager with MecQ™

    Conveyor maintenance must be efficient to avoid expensive, unplanned downtime. This is particularly important in industries like food and beverage production, logistics warehousing, automotive manufacturing, mining, and raw material handling. The Fluke ii910 Precision Acoustic Imager with MecQ™ Mode provides a modern solution. It can detect potential problems in conveyor systems before they worsen. This allows maintenance teams to take proactive steps and maximize system performance. Fluke MecQ™...

    บทความ
  • วิธีเปิดตัวตัดการเชื่อมต่อระดับเบรกที่ไม่มีโหลดอย่างปลอดภัยในระบบเซลล์แสงอาทิตย์

    เรียนรู้เกี่ยวกับข้อกำหนดตัวตัดการเชื่อมต่อเบรกที่ไม่มีโหลดของเซลล์แสงอาทิตย์ที่ออกแบบมาเพื่อไม่ทำให้กระแสไฟฟ้าสะดุด

    บทความ
  • เครื่องมือทดสอบ Fluke 190 Series III ScopeMeter®

    เครื่องมือทดสอบ ScopeMeter รวมความสามารถในการพกพาที่มีความทนทานเข้ากับออสซิโลสโคปตั้งโต๊ะประสิทธิภาพสูง

    ผลิตภัณฑ์
  • ตั้งแต่เครื่องมือตรวจหารอยรั่วอัลตราโซนิคไปจนถึงการตรวจหารอยรั่วของอากาศจากเทคโนโลยีสร้างภาพจากเสียงสะท้อน

    วิธีที่การเปลี่ยนเครื่องมือตรวจหารอยรั่วอัลตราโซนิคเป็นเครื่องมือตรวจหาแสดงภาพรอยรั่วของอากาศด้วยกล้องถ่ายภาพเสียงระดับอุตสาหกรรม ii900 ช่วยมอบ ROI และเพิ่มประสิทธิภาพของกำลังการผลิต

    บทความ
  • 43X II PRODUCT Brochure

    เอกสาร
  • T5 Video Product Tour

    วิดีโอ
  • Ti200 a3001 FC iFlex® Kit

    Quickly identify, diagnose and communicate problems directly from the field with this dynamic kit featuring the Ti200 Thermal Camera and the a3001FC iFlex® module.

    ผลิตภัณฑ์
  • 568 Contact & Infrared Temperature Gun

    เทอร์โมมิเตอร์ IR และ เทอร์โมมิเตอร์สัมผัส แบบทูอินวัน พร้อมด้วยจอแสดงผลดอทเมตริกซ์แบบใหม่

    ผลิตภัณฑ์
  • Fluke 287 FlukeView® Forms Combo Kit

    The Fluke 287 electronics multimeter allows you to log and zoom in on problems. Now compatible with the Fluke Connect mobile app.

    ผลิตภัณฑ์
  • Fluke a3001 FC Wireless iFlex® AC Current Module

    Log and analyze measurement inside a closed cabinet.

    ผลิตภัณฑ์
  • Fluke 27 II Rugged Digital Multimeter

    มาตรฐานใหม่ของคำว่าแข็งแกร่ง

    ผลิตภัณฑ์
  • แคลมป์มิเตอร์ Fluke 381 Remote Display True-rms AC/DC ที่มี iFlex™

    Fluke 381 ทำได้ทุกอย่างที่คุณคาดหวังจากแคลมป์มิเตอร์ อีกทั้งยังสามารถถอดจอแสดงผลเพื่อเพิ่มความยืดหยุ่น ตอนนี้ช่างเพียงคนเดียวสามารถทำงานที่เคยต้องใช้ช่างถึงสองคนได้แล้ว หนีบ Fluke 381 ไว้รอบตัวนำไฟฟ้า ถอดจอแสดงออก และเดินไปอีกมุมของห้องเพื่อควบคุมหรือถอดอุปกรณ์ป้องกัน ทั้งหมดนี้ทำได้ในขณะที่กำลังดูการอ่านค่าในแบบเรียลไทม์

    ผลิตภัณฑ์
  • Fluke Ti400 Infrared Camera

    Fluke Ti400 is perfect for professionals due to high-performance features, like LaserSharp® Auto Focus. Discover the speed and accuracy of this cutting-edge camera today. LaserSharp® Auto Focus tells you exactly where you are focusing – see how

    ผลิตภัณฑ์
  • Fluke Ti300 Infrared Camera

    Fluke Ti300 comes complete with LaserSharp® Auto Focus and a rugged design, built to last in any environment. Stay on the cutting edge with this Fluke infrared camera.

    ผลิตภัณฑ์
  • Fluke 714 Thermocouple Calibrator

    เครื่องมือสอบเทียบเทอร์โมคัปเปิล Fluke 714 มีประสิทธิภาพที่ยอดเยี่ยม ทนทาน และเชื่อถือได้ เครื่องมือส

    ผลิตภัณฑ์
  • Fluke TiR29 Buildings Diagnostic Thermal Imager

    Fluke TiR29 Buildings Diagnostic Thermal Imager

    ผลิตภัณฑ์
  • แคลมป์มิเตอร์ Fluke 373

    แคลมป์มิเตอร์ Fluke 373 รุ่นใหม่ได้ปรับปรุงประสิทธิภาพเพื่อให้เหมาะสำหรับการวัดกระแสไฟฟ้า ac เท่านั้น Fluke 373 คือทุกอย่างที่คุณต้องการ ไม่ว่าจะเป็นการวัดแรงดันไฟฟ้าและกระแสไฟฟ้า ac แบบ true-rms และการวัดความต้านทานถึง 6000Ω ด้วยการตรวจหาต่อเนื่อง และยังทำได้มากกว่านี้

    ผลิตภัณฑ์
  • Fluke 707 Current Loop Calibrator with Quick Click Knob

    เครื่องมือที่รวดเร็วที่สุดและใช้งานด้วยมือเดียวเพื่อตรวจสอบลูป

    ผลิตภัณฑ์
  • Fluke 481 DESI Ion Chamber Survey Meter

    The Fluke 481 Radiation Detection Meter is a portable and practical means for discovering irradiated goods, and for helping remediate contaminant and safety issues while minimally affecting performances.

    ผลิตภัณฑ์
  • CNX C3003 Modular 3-Compartment Soft Case

    Compatible with Fluke CNX wireless modules and meters Three adjustable compartments, inner pocket, and carrying handle

    ผลิตภัณฑ์
  • Fluke i30 AC/DC Current Clamp

    The i30 current clamp is based on Hall Effect technology for use in measurement of both DC and AC current.

    ผลิตภัณฑ์
  • Fluke FVF-SC2 FlukeView Forms Software with Cable

    FVF-SC2 FlukeView Forms Software with cable for Fluke 180 Series.

    ผลิตภัณฑ์
  • เลนส์เทเลโฟโต้อินฟราเรดอัจฉริยะ กำลังขยาย 4 เท่า

    เลนส์เทเลโฟโต้อินฟราเรดอัจฉริยะ กำลังขยาย 4 เท่า จาก Fluke สำหรับ TiX580, TiX501, Ti480 PRO, Ti401 PRO เหมาะสำหรับงานปิโตรเคมี ระบบสนับสนุนการผลิตไฟฟ้า และงานขัดเงาโลหะ

    ผลิตภัณฑ์
  • Why clean power is critical to smooth operations

    When optimizing productivity in industry, energy use is one of the few inputs you can readily control.

    บทความ
  • ROI on industrial energy efficiency cost savings

    ROI for industrial energy efficiency programs. How manufacturing plants can identify energy waste, save on utilities, and industrial energy costs.

    บทความ
  • FlukeView® for ScopeMeter® Test Tools Updates and Demo Software Download

    Upgrade to FlukeView version 5.4 (.exe)   Application software for download, analysis and reporting. Used with Fluke 190 Series II, Fluke 120 Series, Fluke 19xB/C Series and Fluke 2x5C Series. This is a demo version with limited functionality. The full version can be obtained with activation key that is available as an option. Release notes: Relative to the previous version the following changes have been implemented: Support for increased amount of memory locations in newer Fluke-104 and Fluke-204...

    บทความ
  • Fluke 75X Version 1.03 Firmware Upgrade

    Applies only to Firmware Version 1.00, 1.01 and 1.02 To upgrade your 75X to the latest firmware, follow these simple instructions: Download Fluke?75X Version 1.03 firmware upgrade and save the firmware upgrade file. Ensure your Fluke 75x is connected to your Windows PC computer via USB cable and using the battery charger for power. Run the file and follow the instructions for doing the update. Do not turn off the PC or the 75x while the update is in progress. Once the update is complete, cycle the...

    บทความ
  • Fluke 709H Product Demo

    วิดีโอ